TCT-426 Electrocardiographically Gated Intravascular Image Segmentation Enables More Reproducible Volumetric Analysis of Atheroma Burden
Catheterization and cardiovascular interventions(2021)
摘要
Background Volumetric intravascular ultrasound (IVUS) analysis is currently performed at a fixed frame interval, neglecting the cyclic changes in vessel dimensions occurring during the cardiac cycle that can affect the reproducibility of the results. Analysis of end-diastolic (ED) IVUS frames has been proposed to overcome this limitation. However, at present, there is lack of data to support its superiority over conventional IVUS. Objectives The present study aims to compare the reproducibility of IVUS volumetric analysis performed at a fixed frame interval and at the ED frames, identified retrospectively using a novel deep-learning methodology. Methods IVUS data acquired from 97 vessels were included in the present study; each vessel was segmented at 1 mm interval (conventional approach) and at ED frame twice by an expert analyst. Reproducibility was tested for the following metrics; normalized lumen, vessel and total atheroma volume (TAV), and percent atheroma volume (PAV). Results The mean length of the analyzed segments was 50.0 +/- 24.1 mm. ED analysis was more reproducible than the conventional analysis for the normalized lumen (mean difference: 0.76 +/- 4.03 mm(3) vs. 1.72 +/- 11.37 mm(3); p for the variance of differences ratio < 0.001), vessel (0.30 +/- 1.79 mm(3) vs. -0.47 +/- 10.26 mm(3); p < 0.001), TAV (-0.46 +/- 4.03 mm(3) vs. -2.19 +/- 14.39 mm(3); p < 0.001) and PAV (-0.12 +/- 0.59% vs. -0.34 +/- 1.34%; p < 0.001). Results were similar when the analysis focused on the 10 mm most diseased segment. The superiority of the ED approach was due to a more reproducible detection of the segment of interest and to the fact that it was not susceptible to the longitudinal motion of the IVUS probe and the cyclic changes in vessel dimensions during the cardiac cycle. Conclusions ED IVUS segmentation enables more reproducible volumetric analysis and quantification of TAV and PAV that are established end points in longitudinal studies assessing the efficacy of novel pharmacotherapies. Therefore, it should be preferred over conventional IVUS analysis as its higher reproducibility is expected to have an impact on the sample size calculation for the primary end point.
更多查看译文
关键词
intravascular ultrasound,machine learning,near-infrared spectroscopy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn