Work of Breathing During Proportional Assist Ventilation As a Predictor of Extubation Failure.
RESPIRATORY CARE(2023)
摘要
BACKGROUND:Despite decades of research on predictors of extubation success, use of ventilatory support after extubation is common and 10-20% of patients require re-intubation. Proportional assist ventilation (PAV) mode automatically calculates estimated total work of breathing (total WOB). Here, we assessed the performance of total WOB to predict extubation failure in invasively ventilated subjects.METHODS:This prospective observational study was conducted in 6 adult ICUs at an academic medical center. We enrolled intubated subjects who successfully completed a spontaneous breathing trial, had a rapid shallow breathing index < 105 breaths/min/L, and were deemed ready for extubation by the primary team. Total WOB values were recorded at the end of a 30-min PAV trial. Extubation failure was defined as any respiratory support and/or re-intubation within 72 h of extubation. We compared total WOB scores between groups and performance of total WOB for predicting extubation failure with receiver operating characteristic curves.RESULTS:Of 61 subjects enrolled, 9.8% (n = 6) required re-intubation, and 50.8% (n = 31) required any respiratory support within 72 h of extubation. Median total WOB at 30 min on PAV was 0.9 J/L (interquartile range 0.7-1.3 J/L). Total WOB was significantly different between subjects who failed or were successfully extubated (median 1.1 J/L vs 0.7 J/L, P = .004). The area under the curve was 0.71 [95% CI 0.58-0.85] for predicting any requirement of respiratory support and 0.85 [95% CI 0.69-1.00] for predicting re-intubation alone within 72 h of extubation. Total WOB cutoff values maximizing sensitivity and specificity equally were 1.0 J/L for any respiratory support (positive predictive value [PPV] 70.0%, negative predictive value [NPV] 67.7%) and 1.3 J/L for re-intubation (PPV 26.3%, NPV 97.6%).CONCLUSIONS:The discriminative performance of a PAV-derived total WOB value to predict extubation failure was good, indicating total WOB may represent an adjunctive tool for assessing extubation readiness. However, these results should be interpreted as preliminary, with specific thresholds of PAV-derived total WOB requiring further investigation in a large multi-center study.
更多查看译文
关键词
mechanical ventilation,weaning,noninvasive ventilation,endotracheal tube,rapid shallow breathing index,extubation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn