New York Heart Association Functional Class and Implantable Cardioverter-Defibrillator in Non-Ischaemic Heart Failure with Reduced Ejection Fraction: Extended Follow-Up of the DANISH Trial
EUROPEAN JOURNAL OF HEART FAILURE(2024)
摘要
Aims: Current guidelines recommend implantable cardioverter-defibrillator (ICD) therapy in patients with heart failure, a left ventricular ejection fraction of <= 35%, and New York Heart Association (NYHA) class II-III. However, the evidence regarding the benefit of primary prevention ICD is less consistent in patients with NYHA class III. We investigated the long-term effects of primary prevention ICD implantation according to NYHA class in an extended follow-up study of the DANISH trial. Methods and results: The DANISH trial randomized 1116 patients with non-ischaemic heart failure with reduced ejection fraction (HFrEF) to ICD implantation or usual care. Outcomes were analysed according to NYHA class at baseline (NYHA class II and III/IV). The primary outcome was all-cause mortality. Of the 1116 patients randomized in the DANISH trial, 597 (53.5%) were in NYHA class II at baseline, 505 (45.3%) in NYHA class III, and 14 (1.3%) in NYHA class IV. During a median follow-up of 9.5 years, NYHA class III/IV, compared with NYHA class II, were associated with a greater long-term rate of all-cause mortality (hazard ratio [HR] 1.52, 95% confidence interval [CI] 1.20-1.93) and cardiovascular death (HR 1.95 [1.47-2.60]). ICD implantation, compared with usual care, did not reduce the long-term rate of all-cause mortality (all participants: HR 0.89 [95% CI 0.74-1.08]; NYHA class II: HR 0.85 [0.64-1.13]; NYHA class III/IV: HR 0.89 [0.69-1.14]; p(interaction) = 0.78) or cardiovascular death (all participants: HR 0.87 [95% CI 0.70-1.09]; NYHA class II: HR 0.78 [0.54-1.12]; NYHA class III/IV: HR 0.89 [0.67-1.19]; p(interaction) = 0.58), irrespective of NYHA class. Similarly, NYHA class did not modify the beneficial effects of ICD implantation on sudden cardiovascular death (all participants: HR 0.60 [95% CI 0.40-0.92]; NYHA class II: HR 0.73 [0.40-1.36]; NYHA class III/IV: HR 0.52 [0.29-0.94]; p(interaction) = 0.39). Conclusions: In patients with non-ischaemic HFrEF, ICD implantation, compared with usual care, did not reduce the overall mortality rate, but it did reduce sudden cardiovascular death, regardless of baseline NYHA class.
更多查看译文
关键词
Heart failure,Implantable cardioverter-defibrillator,Cardiac resynchronization therapy,Clinical trial,NYHA functional class
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn