High-resolution monitoring and simulation of the temperatures in a borehole heat exchanger field over multiple years

2024 Research Conference Proceedings of the IGSHPA(2024)

引用 0|浏览0
摘要
Installation and operation of ground source heat pump systems build upon an enormous practical experience. As these systems are operated for decades, their techno-economic tenability strongly depends on the long-term in-situ heat transfer efficiency and thus the altered ambient subsurface temperatures. Imbalanced seasonal heat exchange causes thermal changes in the ground, which need to be understood to reliably predict the performance of a system during its lifetime. Despite extensive research, understanding the interaction between subsurface and borehole heat exchangers (BHEs) remains inconclusive and not thorough enough. This is due to the scarcity of detailed monitored sites and the monitoring time needed, which renders model calibration with data over multiple years or decades barely feasible. This study monitors an operational field over six years to better understand subsurface thermal changes induced by BHE operation. The ground source heat pump system supplies heat and cold for a multi-family house in Lausen, Switzerland, and consists of an array of three double-U tubes of 146 m each, along with one observation borehole. Ground temperatures were measured by distributed temperature sensing (DTS) at a temporal resolution of 20 minutes in each BHE as well as in the observation borehole. The thermal conductivity of different subsurface layers was derived through an enhanced thermal response test before the start of operation. The monitored data at the location of the BHEs reveal an annual cooling trend of around 0.55 °C. For the understanding of the controlling factors and processes, these cooling trends and temperature variabilities are reproduced in a numerical model. This is also done to evaluate the predictive capabilities of the model and to ultimately judge the spatial and temporal resolution needed for reliable simulation. Thereby, a three-dimensional U-tube model with heat extraction and free cooling was implemented for the site. Comparison of the simulation against measured data of the three BHEs reveals a fair agreement with a root mean squared error (RMSE) of 0.82 °C, whereas the full variability of observation borehole data cannot be reproduced by the model.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
0
您的评分 :

暂无评分

数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn