Exploring and Validating Heating Dynamics in a Radio-Frequency Electromagnetic Field-Based Resonant Chamber for Mouse Hyperthermia Research.
Electromagnetic Biology and Medicine(2024)
摘要
Mild whole-body hyperthermia has been shown to have anti-tumor effects through an immune-modulating mechanism. Before it is widely applied in the clinic, tremendous mechanistic research in animals is necessary to adhere to evidence-based principles. The radio frequency electromagnetic field (RF-EMF) based heating facility could be a good choice for hyperthermia treatment, but the heating characteristics of a facility, including structure design, electromagnetic and thermal dosimetry, and the biologic effects of hyperthermia, need to be well elucidated. Here, we reported the heating characteristic study on a resonant chamber (RC) excited by a 1800 MHz solid source. The EMF in the RC was stirred by 24 static reflectors, which resulted in the standard deviation of electric field intensity being below 3 dB in the EM homogeneity evaluation. For the exposure scenario, six free-moving mice were loaded into separate cases and exposed simultaneously in the RC. The EMF energy absorption and distribution in exposed mice were calculated with the 12-plane-waves method of numerical simulation. Different levels of core body temperature increment in exposed mice were achieved through regulation of the source output power. Overexpression of heat shock proteins (HSPs) was detected in the liver, lung and muscle, but not in the brain of the exposed mice. The levels of representative inflammatory cytokines in the serum, TNF-alpha and IL-10 increased post RC exposure. Based on the heating characteristic study and validation, the applied RC would be a qualified heating system for mild whole-body hyperthermia effect research in mice. Mild whole-body hyperthermia has potential anti-tumor effects by modulating the immune system. A radio frequency electromagnetic field (RF-EMF)-based heating facility emerges as a suitable option for hyperthermia treatment. However, a qualified heating facility for scientific research must elucidate its heating characteristics and validate the biological effects associated with hyperthermia. In this study, we report the characteristics of a rodent heating chamber using EMF energy. The special structure of the chamber not only achieved efficient EMF usage but also ensured the homogeneity in EMF spatial distribution, animal EM absorption, and EMF-caused biological effects. Our work may offer insights for designing a low-cost yet reliable heating facility for scientific research.
更多查看译文
关键词
Resonant chamber,mild whole-body hyperthermia,numerical simulation,body temperature,heat shock proteins
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn