Application of Metal Artifact Reduction Algorithm in Reducing Metal Artifacts in Post-Surgery Pediatric Low Radiation Dose Spine Computed Tomography (CT) Images

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY(2024)

引用 0|浏览16
摘要
Background: The commonly used methods for removing metal-induced beam hardening artifacts often rely on the use of high energy photons with either high tube voltage or high energy virtual monoenergetic images in dual-energy computed tomography (CT), the radiation dose was usually relatively high in order to generate adequate signals. This retrospective study is designed to evaluate the application of a metal artifact reduction (MAR) algorithm in reducing pedicle screw metal-caused beam hardening artifacts in post-surgery pediatric low radiation dose spine CT images. Methods: Seventy-seven children (3-15 years) who had undergone a low dose CT with 140 or 100 kV were enrolled. The radiation dose was 1.40 mGy for the 3-8 years old and 2.61 mGy for 9-15 years old children. There were 116 pedicle screws evaluated. The raw data were reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) at 50% strength, ASIR-V with MAR (AV-MAR), deep learning image reconstruction (DLIR) at high strength and DLIR with MAR (DL-MAR). The image quality concerning pedicle screws was evaluated objectively in terms of the length of beam-hardening artifact (LHA) and artifact index (AI), and subjectively using a 4-point scale (4 points: best, 3 points: acceptable). Results: Both AV-MAR and DL-MAR significantly reduced metal-induced beam hardening artifacts with smaller LHA (15.76 +/- 10.12 mm, a reduction of 57.24% and 15.66 +/- 10.49 mm, a reduction of 57.40%, respectively), and AI value (62.50 +/- 33.51, a reduction of 64.65% and 61.03 +/- 32.61, a reduction of 65.01%, respectively) compared to ASIR-V and DLIR (all P<0.01), The subjective image quality scores concerning the screws were 3.37 +/- 0.49 and 3.47 +/- 0.50 with AV-MAR and DL-MAR, respectively, higher than the respective value of 1.73 +/- 0.44 and 1.76 +/- 0.43 without MAR (all P<0.01). Conclusions: MAR significantly reduces the low-density artifacts caused by metal screws in post-surgery pediatric low-dose spine CT images, across different tube voltages, radiation dose levels and reconstruction algorithms. Combining DL-MAR further improves the overall image quality under low radiation dose conditions.
更多
查看译文
关键词
Artifacts,tomography,X-ray computed,pedicle screw,pediatrics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
0
您的评分 :

暂无评分

数据免责声明
页面数据均来自互联网公开来源、合作出版商和通过AI技术自动分析结果,我们不对页面数据的有效性、准确性、正确性、可靠性、完整性和及时性做出任何承诺和保证。若有疑问,可以通过电子邮件方式联系我们:report@aminer.cn